Create a new report
Go to Data Entry → Create new report.
Complete the eight sections of the report: Administrative, Patient, Drugs, Reactions, Drug‑Reaction, Other, Assessments, Case summaries.
Setting the Worldwide unique ID (WWUID) and Safety report unique identifier (SRUID)
For manual data entry:
The WWUID consists of: Country code (2‑letter ISO code) + MAH short name + Unique report number (sequential number starting at 00001).
Users must enter the sequential part manually.
The SRUID usually follows the same structure.
Both identifiers remain the same across follow‑ups.
Completing the Report information page
While national guidelines should be followed, some fields have specific technical implications:
Date report was first received (C.1.4): Date received from the primary source. Does not change for follow-ups.
Date of most recent information (C.1.5): Updated each time follow-up information is received.
Does this case fulfil the local criteria for an expedited report? Definition based on local regulatory requirements
SRUID and WWUID: Follow structure → Country code-MAH short name-Unique report number.
Mandatory fields and validation
Empty mandatory fields are highlighted in red when attempting to Submit.
Provide the missing value or use a Null Flavour code where appropriate.
A valid initial report must meet these minimum criteria: identifiable reporter, identifiable patient, at least one suspected drug, and at least one adverse effect.
The platform prevents submission until requirements are met.
Uploading additional documents
Under “Additional documents”, you can upload supporting material.
Describe the content of the file.
Upload the file.
Supported formats: pdf, jpeg, jpg, txt, rtf, tif, html, htm, doc, docx, xls, xlsx, dcm, and png.
Maximum size: 2 MB per file.
Name files clearly; files are stored with the report but are not searchable.
Click Add additional document to upload more files.
Last updated